Chiller Line
65cc89c5d5f9392c39842fa0f45ca356

Hydra is the unit designed for satisfying better the air conditioning requests of your house or your business. They’ve got an updated electronic
system appositely developed by TononForty. This develop the managing of the compressor with a great energy saving and with the
warranty of a long compressor life.
The Adaptive regulation could improve the running time of the compressor accordingly to the automatic and dynamic Set Point and Offset regulation.
These values could be changed by the microprocessor after the comparison between the minimum working time and the effective operating
time of the compressor.
In this way, the unit works for a long period at to the steady conditions and the life of the compressor becomes longer. There is also a great energy
saving and the storage tank becomes unnecessary. Finally, the unit is more compact and could be installed in various places without any trouble.
KRYSTAL

Krystal belong to the collection FORTYchiller, the custom-made air conditioning solutions created for the specific conditioning. it’s an air cooled heat pump with R410a refrigerant, designed for the outdoor installation. this unit has got reduced dimensions and is very noiseless. Accordingly to the European environmental trends, Krystal employs the ecological refrigerant R410a which is actually considered the better in this sector. Krystal has got a range of five sizes whit cooling capacity from 5 to 17 kW; three sizes are available with mono phase electrical supplying.
EPH GEO GENIUS HE

EPH Genius belong to the collection FORTYchiller, the custom-made air conditioning solutions. The Genius system is composed from a reversible heat pump,
a boiler, available in the version with coil heat exchanger too, and an interface appositely designed for heating the domestic hot water.
EPH is a water cooled heat pump, designed for the indoor installation. This unit has got an heat recovery and a device for the desuperheating of the refrigerant.
It’s produced also in the geothermic version called. EPH Genius Geo, which exploit the ground source by means of vertical or horizontal heat exchanger.
There is a range of ten different sizes with heating capacity from 5,5 kW to 38,6 kW, accordingly to the application and the working mode chosen by the
customer.The unit is available in the AP version hydronic kit with water storage tank and circulating pump.
The unit is designed for being supplemented with alternative energies as manifold solar panels.
Accessories:
- coolant gauges; - vibrating dampening support feet; - top remoting kit;
- pressure valve and solenoid valve (only for EPH Genius); - BVA stainless steel tank (200 – 300 – 500 litres); - BVS stainless steel tank with coil heat exchanger (200 – 300 – 500 litres);
- built-in anti-legionella resistance (2 – 3 kW); - hydronic kit pump + heat exchanger; - outside air sensor for dynamic set point;
- geothermic outlet temperature sensor (only for EPH Genius Geo); - supplementary solar manifold temperature sensor.
These accessories are provided separately from the unit and must be installed by the customer.
EPH Genius forma parte de la familia FORTYchiller, una gama creada para la climatización a medida. El sistema Genius está compuesto por una bomba de calor reversible,
un acumulador, disponible también en la versión con serpentín eléctrico complementario y una interfaz preparada para el calentamiento de agua sanitaria.
La bomba de calor reversible EPH, para instalación en interiores, está refrigerada por agua e incluye un recuperador de calor y un dispositivo de desrecalentamiento
del gas refrigerante. Se produce también en la versión geotérmica EPH Genius Geo, que aprovecha el calor del suelo por medio de sondas de profundidad u horizontales.
Las potencias térmicas, según la aplicación elegida y la modalidad de funcionamiento fijada, pueden variar entre los 5,5 kW y los 38,6 kW. Las unidades también
están disponibles en la versión AP con kit hidrónico dotado de depósito de acumulación inercial y bomba de circulación del agua del lado de instalación. La máquina
está preparada para el añadido de otras fuentes de calor alternativas como los colectores térmicos solares.
Accesorios bajo pedido:
- manómetros refrigerantes; - kit de remotización top; - patas de soporte antivibraciones;
- válvula presostática y electroválvula (versión de agua); - acumulador inox BVS versión estándar (200 – 300 – 500 litros); - acumulador inox BVS con serpentín complementario (200 – 300 – 500 litros);
- resistencia complementaria anti-legionela (2 – 3 kW); - kit intercambiador – bomba; - sonda de aire exterior para punto de consigna dinámico;
- sonda de temperatura geotérmica de descarga (versión geotérmica); - sonda de colector solar complementario.
Todos estos accesorios se suministran por separado para su instalación por parte del usuario.
EPH

Cooling capacity 5,2 ÷ 71,8 kW;Heating capacity 6,3 ÷ 84,2 kWEPH (standard): Single unit mounted on powder paintedgalvanised steel bearing structures. Scroll compressor withcrankcase resistance and shut off valve, brazed plate evaporatorand condenser. The cooling circuit has a dehydration filter andliquid/humidity indicator, 4 way valve.Microprocessor regulation also controlss all the workingparameters and active components in the circuit. General isolationswitch with door blocking device.EPH/AP (with storage tank and pump): Separate module:Fitted like the basic version, but with 1 circulation unit or axial pumpfitted, water storage tank, expansion tank, safety valve, flow switch.
EWR

Cooling capacity 4,9 ÷ 117 kWEWR: Single unit mounted on powder painted galvanised steelbearing structures.Scroll compressor on all models with shut off valves from the 22-1 model. Brazed plate evaporator. Condensing coil with copperpipes mechanically expanded into aluminium fins, centrifugal fans.The cooling circuit has a dehydration filter and liquid/humidityindicator (from the 22-1). Microprocessor regulation also controlsall the working parameters and active components in the circuit.KAP: Pumping group in separated unit with supporting structureincluding: Pumps, storiage tank, flow switch, expansion tank, safetyvalve.
EPR

Cooling capacity 4,9 ÷ 117 kW;Heating capacity 5,5 ÷ 137,2 kW.EPR: Single unit mounted on powder painted galvanised steelbearing structures. Scroll compressor on all models with shut offvalves from the 22-1 model.Brazed plate evaporator. Condensing coil with copper pipesmechanically expanded into aluminium fins, centrifugal fans.The cooling circuit has a dehydration filter and liquid/humidityindicator (from the 22-1 model), 4 way valve, liquid receiver.Microprocessor regulation also controls all the workingparameters and active components in the circuit.KAP: Pumping group in separated unit with supporting structureincluding: Pumps, storiage tank, flow switch, expansion tank, safetyvalve.
EWH

Cooling capacity 5,2÷ 72,2 kW - Available versions besides thebasic model: AP single unit with storage tank and pump.EWH (standard): Single unit mounted on powder paintedgalvanised steel bearing structures. Scroll compressor withcrankcase resistance and shut off valve, brazed plate evaporatorand condenser. The cooling circuit has a dehydration filter andliquid/humidity indicator.Microprocessor regulation also controlss all the workingparameters and active components in the circuit. General isolationswitch with door blocking device.EWH/AP (with storage tank and pump): Separate module:Fitted like the basic version, but with 1 circulation unit orcentrigugal pump fitted, water storage tank, expansion tank, safetyvalve, flow switch.
EWH-TO
Cooling capacity 5 - 68,7 kWAvailable versions besides the basic model: AP single unit withstorage tank and pump.EWH (standard): Single unit mounted on powder paintedgalvanized steel bearing structures. Scroll compressor withcrankcase resistance and shut off valve, brazed plate evaporatorand condenser.The cooling circuit has a dehydration filter and liquid/humidityindicator.Microprocessor regulation also controlss all the workingparameters and active components in the circuit. General isolationswitch with door blocking device.EWH/AP (with storage tank and pump): Separate module:Fitted like the basic version, but with 1 circulation unit orcentrifugal pump fitted, water storage tank, expansion tank, safetyvalve, flow switch.
Epa

Cooling capacity 12,5 ÷ 75,4 kW; Heating cap. 14,8 ÷ 91,6 kW.Available versions besides the basic model: AP single unit withstorage tank and pump.EPA (standard): Single unit mounted on a powder paintedgalvanised steel bearing structure. Scroll compressors on allmodels. From the 091 model, the rotalock attachments, servicevalve and liquid/humidity indicator are supplied standard. Blazedplate or srell and tube evaporator. Condensing coil with copperpipes mechanically expanded into aluminium fins. Axial fan withrotating stator blades. Refrigeration circuit complete with a 4 wayinversion dehydration filter, liquid receiver, check valve and fromthe 091 version, the liquid/humidity indicator. Microprocessorregulation to control all the working parameters and activecomponents in the circuit. The device for working at low outsidetemperatures by a condensation temperature control device, aresupplied standard General isolating switch with door blockingdevice. Battery protection grid.EPA/AP (with storage tank and pump): Fitted like the basicversion, but with 1 circulation unit or axial pump fitted, waterstorage tank, expansion tank, saf ety valve, flow limit switch.
Ewa

Cooling capacity 12,9 - 77,7 kWAvailable versions besides the basic model: P single unit with circulationpump; AP single unit withstorage tank and pump; LN low noise version.EWA (standard): Single unit mounted on a powder painted galvanized steelbearing structure. Containing: Scroll compressorwith crankcase resistanceand cut off valves. Brazed plateevaporator on the 151 • 76-2 models.Condensing coil with copperpipes mechanically expanded into aluminiumfins. Axial fans withrotating stator. The cooling circuit is fitted with adehydrating filterand liquid/humidity indicator. Microprocessor regulationto controlall working parameters and active components in the circuit.Device for working at low outside temperatures by temperaturecontroldevice are supplied standard up to model 65-2. Generalisolation switchwith door blocking device. Battery protection grid.EWA/P (with circulaion pump): Fitted like the basic version, but with1 circulation unit or centrifugal pump fitted, safety valve, flow limit switch;EWA/AP (with storage tank and pump): Fitted like the basicversion, butwith 1 circulation unit or centrifugal pump fitted, waterstorage tank,expansion tank, safety valve, flow limit switch.Low noise version LN (Low Noise): Available on all modelsworking at roomtemperature no higher than 38°C. It usescondensers with increased heatexchange surfaces, low speedfans and sound dampening in thecompressor.
Pulsar

Cooling capacity 4,7 ÷ 10,2 kW; Heating capacity 5,2 ÷ 11,2 kW - Only AP version.Single unit mounted on a powder painted galvanized steel bearing structure. Scrollcompressors, brazed plate evaporator immersed in the storage tank, Condensing coil withcopper pipes mechanically expanded into aluminium fins, axial fan with rotating statorblades. Refrigeration circuit complete with dehydration filter, 4 way valve. Microprocessorregulation to control all the working parameters and active components in the circuit. Thedevice for working at low outside temperatures by a temperature control device and thecompressor crankcase heater are supplied standard.The unit contains water circulation unit, water storage tank, safety valve, flow limit switch,4 way valve. Pc control is available using thr optional card: RS232, RS485 outlet.General isolaring switch with door blocking device. Coil protection grid supplied standard.
Quasar

Cooling capacity 4,7 ÷ 10,2 kW - Only AP version.Single unit mounted on a powder painted galvanized steel bearing structure.Scroll compressors, brazed plate evaporator immersed in the storage tank,condensing coil with copper pipes mechanically expanded into aluminium fins, axialfan with rotating stator blades. Refrigeration circuit complete with dehydration filter.Microprocessor regulation to control all the working parameters and activecomponents in the circuit. The device for working at low outside temperatures by atemperature control device, is supplied standard. The unit contains water circulationunit, water storage tank, safety valve, flow limit switch.Pc control is available using thr optional card: RS232, RS485 outlet. Generalisolating switch with door blocking device. Coil protection grid supplied standard.